800-521-0754

Request Information

Request Info

CLOSE

LabRepCo Ultra Series 36 Cu. Ft. Laboratory Refrigerator | Glass Door

Item#: LHUV-36-HG

The LabRepCo LHUV-36-HG Ultra Series laboratory refrigerator is a 36 cu. ft. glass door unit designed for reliable and cost-effective storage of laboratory samples, reagents, and biological materials in clinical and research environments. The system utilizes a microprocessor temperature controller to provide precise monitoring and stable temperature regulation, helping maintain consistent storage conditions for sensitive materials. Energy-efficient R600a hydrocarbon refrigerant and optimized cooling components support low energy consumption while delivering dependable performance. Forced air circulation promotes uniform temperature distribution throughout the cabinet, while integrated audible and visual alarms with remote contacts provide continuous monitoring and system alerts. The self-closing glass door, durable powder-coated steel construction, and adjustable shelving enhance visibility, organization, and everyday laboratory workflow efficiency.

View the previous version of this model, still available for purchase: LHU-36-HG

$6,940.00 $5,343.80

  • Cu. Ft.: 36
  • Door(s): Two (2) swing glass doors, self-closing, magnetic door gasket
  • Exterior Dimensions: 39.625” W x 34.75” D x 81.75” H with casters
  • Interior Dimensions: 34.75"W x 26.5"D x 48.75"H
  • Shelves: Eight (8) adjustable shelves (adjustable in ½” increments)
  • Mounting and Installation: Swivel casters - locking front casters
  • Interior lighting: LED interior lights are safety shielded and switch controlled
  • Airflow Management: Forced draft air circulation, patented air flow technology
  • External probe access: 3/4" probe access port on rear wall
  • Insulation: Cabinet is foamed-in-place with EPA compliant high-density urethane foam
  • Exterior materials: White powder coated steel
  • Access control: Keyed door lock
  • General warranty: Two (2) year parts and labor warranty
  • Compressor warranty: Five (5) year compressor warranty
  • Product Weight (lbs): 355
  • Shipping Weight (lbs): 405
  • Rated Amperage: 3 Amps
  • Power Plug/Power Cord: NEMA 5-15 plug
  • Facility Electrical Requirement: 110-120V AC, 15A breaker, NEMA 5-15 receptacle
  • Agency Listing and Certification: ETL, C-ETL listed. Meets or exceeds ENERGY STAR® v2.0 for Laboratory Refrigerators.
  • Maximum temperature variation (Cabinet air): +/- 2.5° C
  • Stability (Simulator ballast): +/- 0.5° C
  • Adjustable Temperature Range: 2° C to 15° C
  • Stability (Simulator bag): Non-applicable
  • Energy Consumption (KWh/day): <2.2 KWh/day *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
  • Average Heat Rejection (BTU/hr): <570 BTU/h
  • Noise Pressure Level (dBA): 40 dBA or less installed
  • Pull down time to nominal operating temp: < 40 min (empty)

Performance Note: Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

  • Compressor: Hermetic
  • Refrigerant: EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
  • Condenser: Tube and grid, high efficiency fan forced air
  • Evaporator: Fin and tube, high efficiency fan forced air
  • Defrost: Cycle Defrost
  • Controller technology: Microprocessor temperature controller, C°/F° switchable, resolution is 0.1° C/0.2° F
  • Battery Backup: Non-applicable
  • Display Technology: Digital temperature display
  • Display probe: Product simulator bottle with glass bead media
  • External alarm connection: Remote alarm contacts
  • Alarms: Audible and visual high/low temperature alarms, remote alarm contacts

Disclaimers: Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) - improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure

Request a Proposal