Getinge Lancer LSS 130 Laboratory Steam Sterilizers
Item#: LSS130The Getinge Lancer LSS130 is a 130L laboratory steam sterilizer designed for reliable processing of media, glassware, instruments, and laboratory waste. Its chamber supports routine research and production sterilization with programmable cycle control. The system is engineered for repeatable steam sterilization across varied laboratory loads.
User-programmable cycles help laboratories standardize processing for different materials and applications. Integrated monitoring and safety functions support controlled temperature and pressure throughout operation. Durable stainless steel construction supports frequent use and routine cleaning.
Supplier: Getinge
- Internal Volume: 4.6 cu. ft. (130 L)
- Door Configurations: Single Door or Double Door, Pass-through
- Design Operating Temperature: Gravity/Vacuum Cycles: 230°–275°F (110°–135°C) Liquid Cycles: 219°–275°F (104°–135°C)
- Interior Dimensions: 17.5" x 17.5" x 26" (445 x 445 x 660 mm)
- Exterior Dimensions:
- Single Door: 26.25" x 74" x 36.125" (667 x 1880 x 918 mm
- Double Door: 26.25" x 74" x 38.25" (667 x 1880 x 972 mm)
- A safety interlock prevents steam from entering the chamber if the door is not sealed.
- Steam safety valves protect the sterilizer chamber and jacket from over pressurization.
- If the optional powered door encounters an obstruction while closing a safety clutch stops door movement. If the obstruction remains the powered door motor shuts off.
- Real-time pressure in the chamber and jacket is displayed on two analog pressure gauges mounted on the cabinet front. These gauges operate independent of the microprocessor control or electrical power.
- The control system can be configured to automatically check any user-programmed cycle parameters to assure safe and effective cycle performance. If an authorized user attempts to program a cycle beyond recommended parameters a warning will appear.
- Modification of cycle parameters or name requires a supervisor password
- An aborted cycle will generate a warning message and the sterilizer will require operator intervention before the chamber door can be opened
- If emergency access to the chamber interior is required the gasket may be retracted manually to protect the door and gasket when opened
- In the unlikely event of a door failure the gasket is designed to relieve pressure. Baffles at the chamber opening direct steam away from the operator.
- The cabinet design includes insulation and heat guards to protect the operator by minimizing temperature on surfaces around the chamber opening and door
- If a high water level in the drain is not corrected automatically, an audible and visual warning will notify the operator
- An Automatic Utilities Control (AUC) provides a seven-day timer for programmed start-up and shutdown of all systems. When activated, the AUC shuts off water and steam valves to the sterilizer, including the optional electric steam generator, to save energy. Cycles running during these shutoff times will proceed until completed.
- Lancer sterilizers are 90% recyclable by weight and produce no harmful byproducts
Request a Proposal