Molecular Devices FlexStation 3 Multi-Mode Microplate Reader
Item#: FlexStation 3The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling allows for perfectly timed, automated biochemical and cell-based assays. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics.
Supplier: Molecular Devices
- Dimensions: 19" (H) x 23" (W) x 16" (D)
- Weight: 50 lbs. (22.7 kg)
- Power consumption: 500 VA
- Power source: 90–240 Vac, 3.5 A, 50–60 Hz
- Robotic-compatible: Yes
- Plate formats 6, 12, 24, 48, 96, 384 wells
- Light source Xenon flash lamp (1 joule/flash)
- Detectors: 2 photomultiplier tubes (PMT)
- Shaker time: 0 to 999 seconds
- Temp. control: 2°C above ambient to 45°C
- Temp. uniformity: ±1°C at 37°C set point
- Temp. accuracy: ±1°C for reading chamber
- Flex reading: Abs + fluidics, FI + fluidics, Lum + fluidics
- Endpoint reading: All modes + fluidics
- Kinetic reading: All modes + fluidics
- Spectral scanning: All modes + fluidics
- Well scanning: Abs, FI, TRF, Lum
- Fluidics:
- Max. volume-
- 8-channel: 200 µL
- 16-channel: 30 µL
- Precision-
- 8-channel: 2% CV@ 50 µL
- 16-channel: 3% CV @ 10 µL
- Precision-
- 8-channel: 8% CV @ 5 µL
- 16-channel: 5% CV @ 1 µL
- Dispense max. rate-
- 8-channel: 208 µL/sec.
- 16-channel: 52 µL/sec
- Max. volume-
- Read modes:
- Absorbance Fluorescence (top/bottom read)
- Luminescence (top/bottom read)
- Time-Resolved Fluorescence (top/bottom read)
- Fluorescence Polarization (top read)
- HTRF (top/bottom read)
To see all features and specifications see attached specification sheet
- Onboard pipettor: Integrated 8-channel or 16-channel pipettor increases assay flexibility by transferring reagents from 96 or 384 distinct wells in a source plate to the read plate.
- Low volume applications: SpectraDrop™ Micro-Volume Microplate offers a high-throughput solution for low volume measurement, accelerating sample preparation time and increased productivity in DNA, RNA and protein research.
- Optimal assay excitation: Dual monochromators allow users to target the optimal assay excitation and emission wavelengths and eliminate the need to change expensive band pass filters between experiments.
- Robot integration: The FlexStation 3 reader can be integrated with all leading partner robots and with our out-of-the-box automation solution for savings on up-front integration time and resources.
- Enable more assay conditions: Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate.
- Automate pipetting: Improve assay quality and increase throughput with automated pipetting ensuring consistent addition time and minimizing errors, thus providing tighter assay CVs within and between experiments.
- Validate your reader: Get fluid transfer validation with our PathCheck Feature to quantify pipettor head performance. Use it with SoftMax® Pro Software and IQ/OQ/PQ validation protocols for FDA 21 CFR Part 11 compliance.
FlexStation® 3 Multi-Mode Microplate Reader
Request a Proposal
Related Products
-
Item #: MR9610
$16,534.07$14,880.66 -
Item #: MR9611
$17,577.32$15,819.59 -
Item #: MR9620
$26,344.04$25,026.84 - Item #: AQUAMAX
- Item #: SPECTRAMAX-i3x
- Item #: SPECTRAMAX iD3s & iD5e
- Item #: SpectraMax M Series
- Item #: SpectraMax Mini