800-521-0754

Request Information

Request Info

CLOSE

NuAire In-VitroCell ES NU-5800 Direct Heat CO2 Incubator | 7.06 cu. ft. (200L)

Item#: NU-5800

NuAire NU-5800 7.06 cu. ft. direct heat CO2 incubator is designed to provide stable environmental control for tissue culture, embryo development, and biological research applications in biotechnology, pharmaceutical, and academic laboratories. This In-VitroCell ES incubator uses direct heating elements surrounding the growth chamber to maintain uniform temperature conditions while supporting precise CO2 regulation for sensitive cell culture environments. The system incorporates infrared CO2 sensing, microprocessor-based environmental control, and integrated communication outputs including USB, RS-485, and 4–20 mA for monitoring and data logging within laboratory management systems. Key specifications include a temperature control range from 5°C to 55°C with ±0.35°C uniformity at 37°C, CO2 control from 0.1% to 20% with ±0.1% accuracy, and a 7.06 cu. ft. (200 L) chamber with adjustable stainless steel shelving and integrated humidity support.

Request a Quote
Supplier:

Dimensions:

  • Exterior Dimensions (W x D x H): 26.75 x 27.12 x 41.5 in. (679.5 x 689 x 1054 mm)
  • Foot Print (W x D): 23.75 x 20.75 in. (603.2 x 527.1 mm)
  • Interior Dimensions (W x D x H): 21.5 x 21 x 26.5 in. (546.1 x 533.4 x 673.1 mm)
  • Volume: 7.06 ft3 (200 L)
  • Net Weight: 235 lbs (106 kg)

Temperature Control:

  • Control Range: 5° above ambient (to a 30° max ambient) to 55°
  • Set-Point Range: 5°C to 55°C (37.0 Default)
  • Uniformity: ±0.35°C @ 37°C
  • Accuracy: ± 0.1°C
  • Recovery: 0.12°C/min. on Average
  • Display Resolution: 0.1°C
  • Door and Perimeter Heater Control Logic: Base Duty Cycle set to chamber temperature Set-Point Proportional 0-100% [manually adjustable]
  • Temperature Sensor Type: Precision Integrated Circuit

CO2 Control Standard:

  • Range: 0.1 to 20% 5% Default Set Point
  • Accuracy: ±0.1%
  • CO2 Recovery: Up to 5% ±0.2% / -0.5 in 5 minutes Average
  • CO2 Display Resolution: 0.1%
  • CO2 Control Logic: Fixed Algorithm/Manual, Environmental Adaptable
  • CO2 Sensor Type: Infrared (NDIR)
  • Four (4) Stainless Steel Shelves
  • Eight (8) Stainless Steel Shelf Guides
  • Four (4) Shelf elf Brackets
  • Field Reversible Outer Door
  • Remote Alarm Output Contacts
  • 4 to 20 mA Analog Output
  • RS-485 Communication
  • USB Port
  • CO2 Sample Port
  • Adjustable Leg Levelers
  • Access Port and plug with breather holes
  • One (1) Water Pan
  • One (1) 6.5 ft. / 2 m Electrical Cord
*** Laboratory testing shows that, when cleaned regularly, CuVerro® antimicrobial copper surfaces kill greater than 99.9% of the following bacteria within 2 hours of exposure: MRSA, Staphylococcus aureus, Enterobacter aerogenes, Pseudomonas aeruginosa, and E. coli O157:H7. CuVerro® antimicrobial copper surfaces are a supplement to and not a substitute for standard infection control practices and have been shown to reduce microbial contamination, but do not necessarily prevent cross contamination; users must continue to follow all current infection control practices, including those practices related to cleaning and disinfection of environmental surfaces. CuVerro® is a registered trademark of GBC Metals, LLC and is used with permission. NA-003-1208

Request a Proposal