LabRepCo Ultra Series 72 Cu. Ft. Pharmacy Refrigerator with Solid Doors provides reliable, energy-efficient storage for pharmaceuticals, vaccines, and other temperature-sensitive products in healthcare and clinical environments. A microprocessor temperature controller delivers precise temperature monitoring and control, while environmentally friendly R600a refrigerant helps reduce operating costs and energy consumption. Solid insulated doors and adjustable shelving help maintain stable storage conditions while keeping medication inventories organized and secure. Equipped with keyed door locks, remote alarm contacts, audible and visual temperature alarms, and an included pharmacy refrigerator/freezer toolkit, this refrigerator delivers dependable performance for compliant pharmaceutical storage.

View the previous version of this model, still available for purchase: LHU-72-SD-PH

$9,374.00 $7,217.98

  • Cu. Ft.: 72
  • Door(s): Three (3) swing solid doors, self-closing, two right hinged, one left hinged, magnetic door gasket
  • Exterior Dimensions: 81” W x 34.75” D x 81.75” H with casters
  • Interior Dimensions: 76.25"W x 25"D x 48.75"H
  • Shelves: Twelve (12) adjustable shelves (adjustable in 1/2" increments)
  • Mounting and Installation: Swivel casters - locking front casters
  • Interior lighting: LED interior lights are safety shielded and switch controlled
  • Airflow Management: Non-applicable
  • External probe access: 3/4" probe access port on rear wall
  • Insulation: Cabinet is foamed-in-place with EPA compliant high-density urethane foam
  • Exterior materials: White powder coated steel
  • Access control: Keyed door lock
  • General warranty: Two (2) year parts and labor warranty
  • Compressor warranty: Five (5) year compressor warranty
  • Product Weight (lbs): 600
  • Shipping Weight (lbs): 705
  • Rated Amperage: 3 Amps
  • Power Plug/Power Cord: NEMA 5-15 plug
  • Facility Electrical Requirement: NEMA 5-15P plug, vaccine storage power cord warning label
  • Agency Listing and Certification: ETL, C-ETL listed: certified to UL471 standard. Meets or exceeds Energy Star v2.0 for Laboratory Refrigerators.
  • Maximum temperature variation (Cabinet air): +/- 2.5° C
  • Stability (Simulator ballast): +/- 0.5° C
  • Adjustable Temperature Range: 36° F to 46° F (2° C to 8° C), Calibrated using a NIST traceable device, certificate included
  • Energy Consumption (KWh/day): <2.8 KWh/day *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
  • Average Heat Rejection (BTU/hr): <720 BTU/h
  • Noise Pressure Level (dBA): 40 dBA or less installed
  • Pull down time to nominal operating temp: <60 min (empty)

Performance Note: Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

  • Compressor: Hermetic
  • Refrigerant: EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
  • Condenser: Tube and grid, high efficiency fan forced air
  • Evaporator: Fin and tube, high efficiency fan forced air
  • Defrost: Cycle Defrost
  • Controller technology: Microprocessor temperature controller
  • Battery Backup: Non-applicable
  • Display Technology: Non-applicable
  • Display Communication: Non-applicable
  • External alarm connection: Remote alarm contacts
  • Display probe: Product simulator bottle with glass bead media
  • Alarms: Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm
  • Included accessories: Pharmacy refrigerator/freezer toolkit

Disclaimers: Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) - improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure