800-521-0754

Request Information

Request Info

CLOSE

CliniCool© Series 1.7 Cu. Ft. Undercounter NSF Certified Pharmacy/Vaccine Freezer | Freestanding

Item#: LHP-2-FM-PHNSF*

The CliniCool© Series LHP-2-FM-PHNSF is a 1.7 cu. ft. freestanding medical freezer certified to NSF/ANSI 456 for vaccine storage. It operates from -15°C to -28°C with microprocessor temperature control. The solid locking door and three shelves provide secure storage for vaccines and pharmaceuticals. Audible and visual temperature alarms and remote contacts support critical temperature monitoring. A calibrated probe and access port provide additional capabilities for monitoring stored materials. The freezer uses R600a refrigerant and is compatible with Pyxis®, Omnicell®, and AcuDose RX® systems.

Please note this product ships freight

What does NSF certified vaccine storage mean? Click here to learn more

*Eligible for QuickShip*

$2,200.00 $1,694.00

  • Temperature setpoint range: -15°C to -28°C (Controller settings must remain unaltered to ensure thermal performance compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
  • Operational environment: Indoor use only. Optimal operating range: +18°C to +26°C (+65°F to +78°F), 70% RH
  • Exterior Dimensions (WxDxH): 23 5/8" x 23" x 20 3/8"
  • Interior Dimensions (WxDxH): 17 3/4" x 16" x 12 7/8"
  • Storage capacity: 1.7 cu. ft. gross volume
  • Door: One swing solid door, self-closing, right hinged, non-reversible, magnetic sealed gasket, keyed lock
  • Shelves: Three shelves (two adjustable/one fixed) with guard rail on back
  • Mounting: Leveling legs. Note: 4" of clearance on all sides must be maintained for adequate ventilation
  • Interior lighting: N/A
  • External probe access: Rear wall port (3/8") dia.
  • Insulation: Cabinet is foamed-in-place with EPA compliant high density urethane foam
  • Exterior materials: White powder coated steel
  • Access control: Pyxis®, Omnicell® and AcuDose RX® compatible
  • Warranty: 2 years parts and labor with an additional 3 years parts only on the compressor
  • Product Weight: 80 lbs.
  • Shipping Weight: 106 lbs.
  • Rated Amperage: 1.0 Amps
  • Power Plug/Power Cord: NEMA 5-15 plug, 8 to 10 ft typical, conforms to UL471 requirements, Vaccine storage power cord warning label
  • Facility Electrical Requirement: 110-120V AC: 15 A (minimum)
  • Agency Listing and Certification: Certified in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. UL, C-UL, ETL, C-ETL listed (either single or dual agency listings) and certified to UL471 standard, hydrocarbon refrigerant safety.
  • Included Accessories:
    • Pharmacy refrigerator/freezer toolkit and temperature logs

 

Performance
  • Uniformity (Cabinet air): +/- 2.7°C
  • Stability (Cabinet air): +/- 2.0°C
  • Maximum temperature variation (Cabinet air): +/- 3.3°C
  • Temperature rise after an after 8 sec door openings: Temperature did not exceed -19°C at any probe for all required NSF/ANSI 456 testing protocols
  • Recovery after 3 min door opening: All probes recover to under -15°C within 3.2 min.
  • Energy consumption: 0.75 KWh/day
  • Average heat rejection: 1.27 KWh/day (180 BTU/h)
  • Noise pressure level (dBA): 34 or less installed
  • Pull down time to nominal operating temp: 100 min

Note: The CDC requires a data logger or temperature monitoring device to consistently record live temperature readings from the inside of a refrigerator or freezer when storing all types of vaccines. Constant monitoring of vaccines at recommended temperatures is essential for maintaining the efficacy of a vaccine. Failing to do so can lead to wasted vaccines or ineffective vaccines being administered to patients. Please follow the CDC requirements for Vaccine Storage & the COVID-19 Vaccination Program found here.

 

*Eligible for QuickShip*

Controller, Configuration, Alarms and Monitoring
  • Controller technology: Parametric, microprocessor, LED display with 0.1°C resolution
  • Temperature setpoint range: -15°C to -28°C (Controller settings must remain unaltered to ensure thermal performance compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
  • Display probe: Calibrated, stainless steel
  • External alarm connection: 
    • State switching remote alarm contacts.
    • Visual and audible indicators.
  • Alarms: High / Low temperature, compliant with alarm requirements defined in the NSF/ANSI 456 Standard for Vaccine Storage
  • Simulator ballast: glass bead thermal media
Refrigeration System
  • Compressor: Hermetic, high performance
  • Refrigerant: EPA SNAP compliant, R600a, Isobutane
  • Condenser: Tube and grid construction, fanless
  • Evaporator: Integrated cold wall design
  • Defrost: Manual

Request a Proposal