BioStore -190°C LN2-Based Automated Storage System for Cryo Cassettes is the only fully automated liquid nitrogen based system, capable of handling a wide range of cryo cassettes including 250ml sizes; the new standard in secure, documented cryo cassette storage.

  • Smooth, automated cassette handling
  • Insulating tower for temperature stability
  • Fully integrated inventory management
  • Reports to support 21-CRF-11 compliance
  • 17-21 days of emergency hold time
  • Capacity of 990 cryo cassettes
Request a Quote

System Dimensions

  • Height: 125’’ (3,175mm)
  • Width: 60” (1,524mm)
  • Depth: 79’’ (2,007mm)
  • Storage Capacity: (990) 250ml Cryo Cassettes
  • Weight (empty): 2,433lbs (1,105kg)
  • Weight (full): 3,548lbs (1,612kg)
  • Maximum Floor Load: 108lbs/ft2 (528kg/m2)
  • Maximum Point Load: (4-points) 887lbs (403kg)

Electrical

  • Voltage: 110V, Single Phase
  • Amps: 2A
  • Power Output (Idle): 100 Watts
  • Power Output (MAX): 220 Watts
  • Plug Type: NEMA 5-15
  • LN2: IEC TYPE B (IEC TYPE F)
  • Connection Type / Size: 1/2” NPT Female Fitting to existing Vacuum Jacket line
  • Supply Pressure (open valve): 22-35 psig (1.52-2.41bar)
  • Capacity (Vapor Phase): 295L
  • Static Evaporation Rate (nominal): 13.6L/day (11.00kg/day)
  • Static Holding Time Vapor: 21 days

Operating Environment

  • Temperature: 65°F-80°F (18°C-27°C)
  • Humidity: Max 50% rH (non-condensing)
  • Operating Temperature: -310°F or lower (-190°C or lower)

 

  • Warranty: 1-Year; includes onsite service, travel, and spare parts. Preventative maintenance and wear parts not included.
  • Other: Installation and operator training included
  • Regulatory Compliance China RoHS, Conflict Materials, EU REACH, EU RoHS, CE Mark Directives [MachineryDirective, EMC Directive, and RoHS Directive]

Sample Integrity, Security & Tracking

  • Consistent -190°C temperatures achieved for from top to bottom using LN2 vapor
  • A sample integrity calculator protects samples from excessive warming by predicting their temperatures based on experimental evidence
  • Integrity is further enhanced by protecting innocent samples during storage and retrieval transient exposures
  • Racks are quickly pulled into an insulated sleeve, significantly slowing transient warming
  • 20-day safety hold time below -135°C (Tg) with full manual access if power or LN2 are disrupted
  • Comprehensive inventory management with vial-level ID, audit trail, reports, and LIMS connectivity

Software

  • BioStore controller software and touchscreen enable efficient order management and execution
  • Its easy-to-use graphical interface permits tube-level inventory management plus sample storage, retrieval, and auditing
  • The software monitors storage environment data and has comprehensive error handling
  • LIMS connectivity is available for real-time sample management
  • Full 21-CFR-11 reporting capability is available
  • Administrator-defined libraries and access control can optimize the system as a shared resource

Azenta Life Sciences BioStore Solutions Brochure

Download

Azenta Automated Laboratory Cold Storage Brochure

Download

Azenta Cryo Freezer Operator Manual

Download

[White Paper] Sample Warming During Innocent Exposures

Download

[White Paper] Effects of Transient Warming

Download

BioStore™ Cryogenic Storage: A Cryogenic Automated Sample Storage System with a Smaller Footprint


Request a Proposal