The CliniCool Ultra Elite series NSF certified solid door medical refrigerators are designed specifically for the storage of a variety of vaccines, pharmaceuticals and other temperature sensitive materials often used within the clinical and medical industries. These NSF certified medical grade refrigerators provide superior sample security with audible & visual high/ low temperature alarms and remote alarm contacts for complete temperature control and awareness. The LHE-23-SD-PHNSF comes standard with one solid door, digital temperature display & alarm module, microprocessor controller, LED interior lights, 3/8” probe access port and a pharmacy refrigerator/freezer toolkit with temperature logs.

Includes: Temperature Monitor Device - Complies with The Current CDC Guidelines, 3 Years Certification Of Calibration, “Buffered” Probe In The Product Simulated Solution, Min/Max Memory, °F/°C Switchable, Field Installable, And Visual & Audible Temperature Alarms.

What does NSF certified vaccine storage mean? Click here to learn more

$8,962.00 $6,900.74

Request a Quote
  • Temperature setpoint range: +1°C to +10°C (Controller settings must remain unaltered to ensure thermal performance compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
  • Operational environment: Indoor use only, +18°C to +26°C (+65°F to +78°F), <70% RH
  • Storage capacity: 23 cu. ft. gross volume
  • Exterior Dimensions (WxDxH): 26 7/8" x 34 7/8" x 81 3/4"
  • Interior Dimensions (WxDxH): 21 3/4" x 25 1/8" x 49 1/4"
  • Door: One swing solid door, self-closing, right hinged, non-reversible, magnetic sealed gasket, keyed lock
  • Shelves: Seven shelves (six adjustable/one fixed) with guard rail on back
  • Mounting: 3 1/2" Swivel Castors(two locking)
  • Interior lighting: Shielded, switched LED lighting, full coverage, balanced spectrum
  • Airflow management: Forced Air technology, patent pending
  • External probe access: Rear wall port (3/4") dia.
  • Insulation: Cabinet is foamed-in-place with EPA compliant high density urethane foam
  • Exterior materials: White powder coated steel
  • Access control: Pyxis®, Omnicell® and AcuDose RX® compatible
  • General warranty: Two (2) years parts and labor warranty, excluding display probe calibration
  • Compressor warranty: Five (5) years compressor warranty
  • Product Weight: 216 lbs.
  • Shipping Weight: 256 lbs.
  • Rated Amperage: 3 Amps
  • Power Plug/Power Cord: NEMA 5-15 plug, 8 to 10 ft typical, conforms to UL471 requirements, Vaccine storage power cord warning label
  • Facility Electrical Requirement: 110-120V AC: 15 A (minimum)
  • Agency Listing and Certification: Certified in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. UL, C-UL, ETL, C-ETL listed (either single or dual agency listings) and certified to UL471 standard, hydrocarbon refrigerant safety.
  • Included Accessories:
    • Pharmacy refrigerator/freezer toolkit and temperature logs
    • Temperature Monitor Device - Complies with The Current CDC Guidelines, 3 Years Certification Of Calibration, “Buffered” Probe In The Product Simulated Solution, Min/Max Memory, °F/°C Switchable, Field Installable, And Visual & Audible Temperature Alarms

 

Performance
  • Uniformity¹ (Cabinet air): +/- 1.0°C
  • Stability² (Cabinet air): +/- 1.1°C
  • Maximum temperature variation (Cabinet air): +/- 1.4°C
  • Temperature rise after an after 8 sec door openings: Temperature did not exceed 6.7°C at any probe for all required NSF/ANSI 456 testing protocolsᶟ
  • Recovery after 3 min door opening: All probes recover to under 8°C within 4.8 min.
  • Energy consumption: 1.32 KWh/day⁴
  • Average heat rejection: 2.21 KWh/day (315 BTU/h)⁴
  • Noise pressure level (dBA): 49 or less installed
  • Pull down time to nominal operating temp: 30 min

Note: The CDC requires a data logger or temperature monitoring device to consistently record live temperature readings from the inside of a refrigerator or freezer when storing all types of vaccines. Constant monitoring of vaccines at recommended temperatures is essential for maintaining the efficacy of a vaccine. Failing to do so can lead to wasted vaccines or ineffective vaccines being administered to patients. Please follow the CDC requirements for Vaccine Storage & the COVID-19 Vaccination Program found here.

Controller, Configuration, Alarms and Monitoring
  • Controller technology: Parametric, microprocessor, LED display with 0.1°C resolution
  • Display Technology: NSF/ANSI 456 Standard for Vaccine Storage compliant digital temperature display and alarm module with battery back-up, F/C switchable.
  • Temperature setpoint range: +1°C to +10°C (Controller settings must remain unaltered to ensure thermal performance compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
  • Display probe: Calibrated, stainless steel
  • External alarm connection: 
    • State switching remote alarm contacts.
    • Visual and audible indicators.
  • Alarms: High / Low temperature, compliant with alarm requirements defined in the NSF/ANSI Standard for Vaccine Storage
  • Simulator ballast: 20 ml bottle, glass bead thermal media
Refrigeration System
  • Compressor: Hermetic, high performance
  • Refrigerant: EPA SNAP compliant, R290, propane
  • Condenser: Fin and tube design, high efficiency fan
  • Evaporator: Fin and tube design, high efficiency fan
  • Defrost: Cycle optimized, zero energy