PharmaGard ES NU-NTE800 Total Exhaust Compounding Aseptic Containment Isolator
Item#: NU-NTE800The PharmaGard ES NTE800 Total Exhaust Compounding Aseptic Pharmacy Isolator from NuAire use a Restricted Access Barrier Systems (RABS) which creates a negative pressure ISO Class 5 controlled environment for the aseptic compounding of hazardous drugs and complies with USP <800> requirements. These isolators provide multiple levels of protection in order to eliminate contamination and minimize the possibility of chemotherapy agents or other hazardous materials from entering or exiting the work area.
Supplier: NuAire
Tags: Aseptic Containment Isolator, Pharmacy Isolators, USP800Performance Specifications |
NU-NTE800-400
Nominal 4 foot (1.2m)
|
NU-NTE800-600
Nominal 6 foot (1.8m)
|
Product Protection | ISO Class 5 (Laminar Flow) | ISO Class 5 (Laminar Flow) |
Style of Isolator | Bench top/console Isolator | Bench top/console Isolator |
Isolator Construction | Welded stainless steel 16GA, Type 304 pressure tight design | Welded stainless steel 16GA, Type 304 pressure tight design |
Interchange Chamber | ISO Class 5 With Internal/External Sealed Doors | ISO Class 5 With Internal/External Sealed Doors |
Diffuser for Air Supply (Metal) | Non-flammable | Non-flammable |
HEPA Filter Seal Type:
Supply Filter-99.99% Eff. on 0.3 microns
Exhaust Filter-99.99% Eff. on 0.3 microns
|
Neoprene, Spring loaded Under Negative Pressure | Neoprene, Spring loaded Under Negative Pressure |
Standard Services:
Hospital Grade Duplex Outlet
|
One, Backwall | One, Backwall |
Optional Services:
Service Valves 3/8" NPT
|
Up to 3 | Up to 3 |
Work Zone Inches (mm):
Width
Height
Depth (Center of Glove Port):
|
35 1/4 (895)
27 3/8 (695)
23 1/4 (591)
|
59 1/4 (1505)
27 3/8 (695)
23 1/4 (591)
|
Interchange Inches (mm):
Width
Depth (at Work Surface) Height
|
14 1/8 (359)
24 (610)
27 3/8 (695)
|
14 1/8 (359)
24 (610)
27 3/8 (695)
|
Hinged Lockable Viewing Window (Polycarbonate) | Fully closed to fully open | Fully closed to fully open |
Exhaust CFM/CMH Standard: | 550/934 | 725/1232 |
Plan Duct Static Pressure Eng/Metric: (water gauge) | 2.0”w.g./50.8 mm w.g. | 2.0”w.g./50.8 mm w.g. |
Heat Rejected, BTU, Per Hour | 539 | 880 |
Electrical: Volts, AC 60 Hz | UL/UL-C Listed 115 | UL/UL-C Listed 115 |
Amps: Blower/Lights | 3 | 5 |
Amps: Hospital Grade Duplex Amps: Total | 3 | 3 |
12 ft. Hospital Grade Power Cord (one) | 6 | 8 |
14 GA - 3 Wire, 15A | 14 GA - 3 Wire, 15A | |
*Crated Shipping Weight: | 515 lbs./234 kg. | 665 lbs./302 kg. |
*Net Weight: | 465 lbs./211 kg. | 615 lbs./279 kg. |
- Locking interchange compartment
- Incorporates the latest advancements in laboratory ergonomics
- Quick change, air-tight waste disposal system
- Ultra-high efficiency motor increased filter life and lowers energy costs
- Stable, consistent unidirectional airflow
- HEPEX Zero Leak Airflow System
- Technology to reduce unit noise and vibration
- Bag-In/Bag-Out Filter system simplifies filter replacement and protects technicians from contamination